Applied Biosystems Analysis Software Help
Getting started
Analysis workflow
System requirements
Compatible Real-Time PCR System Data
Applied Biosystems Software interface
Best practices and tips for using the software
Video library
Getting started with gene expression
Review data using the Outlier Wheel Plot
Calculations in relative quantitation
Manage your projects and experiment data
Create a project and add experiment data
Manage projects and experiment data
Share experiments, folders, and projects
Experiment data/files
Set up the project
Create or edit an analysis group
Version 1.1 algorithm improvements and settings
Manage samples and targets
Manage biological groups
Configure the analysis settings
Import sample information from design files
Import target information from AIF
Define endogenous controls for the analysis
Edit experiment properties
Review and edit the plate setups
Review the OpenArray QC images
Apply samples and targets
Specify and assign tasks
Specify and assign standards
Plate setup files
Use a plate setup file to apply plate layout information
Review the raw data
Review the quality data
Using the Amplification Plot Histogram
Amplification plot
Multicomponent plot
About the quality data summary
Omit wells from the analysis
Review the analyzed data
Review the analyzed data and plots
Box Plot
Change the Box Plot display
Correlation Plot
RQ plot
Heatmap Plot
Volcano Plot
View and modify the Volcano Plot
Melt Curve Plot
Omitting wells and samples
Export the results
Export the analyzed data from a project
Export project data as a slide presentation
Export plots for presentation and publication
Export data for use in other projects
Screens and plots
Amplification plot
Analysis screen
Box Plot
Correlation Plot
Data Review screen
Export screen
Heatmap Plot
Melt Curve Plot
Multicomponent plot
Outlier Wheel Plot
Overview screen
Plate Setup screen
RQ plot
Volcano Plot
Well Table
Error messages and troubleshooting
Quality flags
AMPNC flag (amplification in negative control)
AMPSCORE (Low signal in linear phase) quality flag
Amp Status (amplification status) value
BADROX flag (bad passive reference signal)
BLFAIL flag (Automatic Baseline Algorithm failed to identify baseline region)
CQCONF flag (calculated confidence in the Cq value is low)
CRTAMPLITUDE flag (low relative amplitude)
CRTNOISE flag (high relative noise)
CTFAIL flag (Baseline Threshold Algorithm failed to identify Ct)
DRNMIN flag (detection of minimum ∆Rn due to abnormal baseline)
EXPFAIL flag (Baseline Threshold Algorithm failed to identify exponential region)
HIGHSD flag (high standard deviation in replicate group)
LOWROX (Low ROX Intensity) quality flag
MAXCT (Cq above maximum) quality flag
MPOUTLIER (ΔCq outlier in multiplex experiment) quality flag
MTP flag (melt curve analysis shows more than one peak)
NOAMP flag (no amplification)
NOISE flag (noise is higher than other wells in plate)
NOSAMPLE (No sample assigned to well) quality flag
NOSIGNAL flag (no signal in well)
OFFSCALE flag (fluorescence signal is offscale)
OUTLIERRG flag (outlier detected in replicate group)
PRFDROP flag (passive reference signal changes significantly near the Cq)
PRFLOW flag (average passive reference signal is below the threshold)
SPIKE flag (noise spikes)
THOLDFAIL flag (Automatic Threshold Algorithm failed to identify threshold)
Documentation and support
Customer and technical support
Limited product warranty
Legal